相比之下,纳伏表[2]具有1000倍高的输入阻抗(也就是10GΩ),因此它可以以±1%精度来测量高于1GΩ的电阻。(消除10GΩ的负载影响只需将输入阻抗精确到±10%,以开路作为测试对象,通过直流反转测量的方法即可得到。)此外,一些电流源提供了保护放大器,这样纳伏表[3]可以测量保护电压而不是直接测量测试对象的电压(图6)。这就将传输至测试对象的电流噪声降低到电流源噪声[4](低于20fA/ )。在引线电阻可以忽略,两线连接至测试对象可以接受的情况下,这种配置可降低了负载误差[5]、噪声及功率。
图6 采用带保护缓冲电路的两线直流反转测量的测试设置(保护源连接提供了一种解决测试电路低阻抗的问题的方式)
[1] 纳米技术:http://www.keithley.com.cn/promo/wb/201
[2] 纳伏表:http://www.keithley.com.cn/products/localizedproducts/lovoltloresist/2182a
[3] 6220型直流精密电流源:http://www.keithley.com.cn/products/dcac/sensitive/lowvoltage/?mn=6220
[4] 电流噪声:http://www.keithley.com.cn/llm/a/25.html
[5] 误差源:http://www.keithley.com.cn/llm/a/29.html